- 100% Pure
- Description :Has overvoltage protection, undervoltage protection and voltage display (voltage measurement), safer and reliable to use.
- What You Get :Both overvoltage protection and overvoltage recovery values are adjustable, and the overvoltage protection action time is adjustable.
- Universal compatible :Both the undervoltage protection value and the undervoltage recovery value are adjustable, and the undervoltage protection action time is adjustable.
- Professional design :The fault recovery delay time and power on delay time are adjustable for better performance.
- Performance :This current protector has the function of reset mode selection, fault query and factory reset.
Product Description
Parameter
1.Over-voltage protection
2.Under-voltage protection
3.Over-current protection
4.Automatic recovery
5.Voltage display(voltage measurement)
6.Current display (current measurement)
7. Voltage calibration: Voltage +-10% adjustable. A13
8. Current calibration: Current +- 9/5% adjustable A15
9. Restore factory settings: press the down button for more than 12s
10.Fault inquiry: Press the UP button from more than 12S
Product Parameters:
1.Model number:TVPS1-63
2.Power supply:230VAC 50/60Hz
3.Max.Loading power: 1~40A Adjustable(default:20A)
1~63A Adjustable(default:40A)
1~80A Adjustable( default:60A)
4.Over-voltage protection value range:230V~300~OFF(default:270V)
Over-voltage recovery voltage range:225V–295V(default:250V)
Over-voltage protection action time:0.1s~30s(default value:1s)
Over-voltage r ecovery delay time:1s~500s(default:30s)
5.Under-voltage protection value range:140V–210V –OFF(default:170V)
Under-voltage recovery voltage range:145V–215V (default:190V)
Under-voltage protection action time:0.1s~30s(default:1s)
Under-voltage r ecovery delay time:1s~500s(default:30s)
6.Over-current adjustment range:1-40A (default:20A) 1-63A (default:40A) 1-80A(default:60A)
Over-current action range:0.1~30 second (default:1s)
Over-current r ecovery delay time:1s~500s(default:30s)
7.Power-on delay time:1s~500s(default:10s)
<;2W
9.Electric machinery life : 100,000 times
10.Installation:35mm DIN rail
110V Version
1.Model number:TVPS1-63C
2.Power supply:110VAC 50/60Hz
3.Max.Loading power:1~63A Adjustable(default:40A)
4.Over-voltage protection value range:80V~300~OFF(default:145V)
Over-voltage recovery voltage range:75V–295V(default:140V)
Over-voltage protection action time:0.1s~30s(default value:1s)
Over-voltage recovery delay time:1s~500s(default:30s)
5.Under-voltage protection value range:80V–300V –OFF(def